{"id":1212,"date":"2023-11-28T17:07:37","date_gmt":"2023-11-28T08:07:37","guid":{"rendered":"https:\/\/www.durastream.com\/en\/ja\/?page_id=1212"},"modified":"2024-06-24T17:07:44","modified_gmt":"2024-06-24T08:07:44","slug":"impact-strength","status":"publish","type":"page","link":"https:\/\/www.durastream.com\/en\/product-comparison\/other-materials\/impact-strength\/","title":{"rendered":"Impact strength"},"content":{"rendered":"<div  class=\"frame pt-0 pb-0\">\r\n\t\t<div class=\"hero-flame-single\" style=\"background-image:url(https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/general-hero1.jpg);\">\r\n\t\t\t<div class=\"hero-flame-single-filter\">\r\n\t\t\t\t<div class=\"hero-title container\">\r\n\t\t\t\t\t\tStrengths of CPVC &#8211; Impact strength\t\t\t\t<\/div>\r\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n<\/div>\n\n<div  class=\"frame pt-3 pb-0\">\r\n\t<div class=\"container\">\r\n    \t<\/div>\r\n<\/div>\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<div class=\"container\">\r\n\t\n<h2  class=\"title-l2\"><span>What is Impact Strength?<\/span><\/h2>\r\n\n\n\n<p>Impact strength is the ability of a material to withstand a sudden load applied to it without rupturing. It is measured in terms of how much energy the material absorbs before rupture.<\/p>\n\n\n<h2  class=\"title-l2\"><span>Why Is Impact Strength Important for CPVC?<\/span><\/h2>\r\n\n\n\n<p>High impact strength enables a product to avoid damage and rupturing from external and internal impact.<\/p>\n\n\n\n<p>In the CPVC piping system, impact strength is a reliable benchmark used to determine superior product performance, longer service life, and low risk of damage during transportation and after implementation.<\/p>\n\n\n\n<p>The chart below shows the typical impact strength for each type of plastic based on compound formulations. We can increase impact strength using the SEKISUI CPVC compound formulation technology.<\/p>\n\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<div  class=\"col2-wrapper  customcol-items-start\">\r\n\t\t\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance1.png\" alt=\"\" class=\"wp-image-2563\" style=\"width:562px;height:auto\" srcset=\"https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance1.png 500w, https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance1-300x300.png 300w, https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance1-150x150.png 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\r\n<div  class=\"image-block justify-content-center\">\r\n\t<figure>\r\n\t\t<img decoding=\"async\" src=\"https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance2.png\" alt=\"Strengths-of-CPVC-Impact-resistance2\">\r\n\t\t\t\t<figcaption class=\"text-center\">&#8220;Test Method: ASTM D256<br>Unit: ft\u30fblb\/in<\/figcaption>\r\n\t\t\t<\/figure>\r\n<\/div><\/div>\n<\/div>\n\n<\/div>\r\n\n\n<h2  class=\"title-l2\"><span>How do you test Impact Strength?<\/span><\/h2>\r\n\n\n\n<p>Impact strength is a material\u2019s ability to withstand a suddenly applied mechanical load. Impact strength tests commonly consist of Charpy and IZOD specimen configuration.<\/p>\n\n\n\n<p>The main difference between the IZOD and Charpy impact tests is the position of the specimen and type of notches.<\/p>\n\n\n\n<p>Set the sample under the machine and rotate the hammer to the swing position. In the IZOD test, the specimen is positioned vertically with the notch facing the hammer. In the Charpy test, the specimen is positioned horizontally with the notch facing away from the hammer.<\/p>\n\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<div  class=\"col2-wrapper  customcol-items-start\">\r\n\t\t\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\r\n<div  class=\"image-block justify-content-center\">\r\n\t<figure>\r\n\t\t<img decoding=\"async\" src=\"https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance3.png\" alt=\"Strengths-of-CPVC-Impact-resistance3\">\r\n\t\t\t\t<figcaption class=\"text-center\">Test piece illustration<\/figcaption>\r\n\t\t\t<\/figure>\r\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\r\n<div  class=\"image-block justify-content-center\">\r\n\t<figure>\r\n\t\t<img decoding=\"async\" src=\"https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance4.png\" alt=\"Strengths-of-CPVC-Impact-resistance4\">\r\n\t\t\t\t<figcaption class=\"text-center\">Izod impact test illustration<\/figcaption>\r\n\t\t\t<\/figure>\r\n<\/div><\/div>\n<\/div>\n\n<\/div>\r\n\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<h2  class=\"title-l2\"><span>Drop Impact Strength<\/span><\/h2>\r\n\n\n\n<p>Drop impact strength measures a material\u2019s ability to withstand external damage, such as damage that occurs during transportation or from falling or being dropped at a jobsite.<\/p>\n\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<h2  class=\"title-l2\"><span>High Drop Impact Strength (Pipe Property)<\/span><\/h2>\r\n\n\n\n<p>&#8220;Durastream&#8221; has high impact resistance. Its performance does not decrease even from long-term use at high temperatures.<\/p>\n\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<div  class=\"col2-wrapper  customcol-items-start\">\r\n\t\t\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\r\n<div  class=\"image-block justify-content-center\">\r\n\t<figure>\r\n\t\t<img decoding=\"async\" src=\"https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance5.png\" alt=\"Strengths-of-CPVC-Impact-resistance5\">\r\n\t\t\t\t<figcaption class=\"text-center\">Test Conditions<br><br>Evaluation after immersing the sample in hot water at 82\u00b0C(179\u00b0F)<br>Weight\uff1a1kg (2.205 Lbs.)<br>50% failure drop height<br>N = 10 pieces<\/figcaption>\r\n\t\t\t<\/figure>\r\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\r\n<div  class=\"image-block justify-content-center\">\r\n\t<figure>\r\n\t\t<img decoding=\"async\" src=\"https:\/\/www.durastream.com\/en\/wp-content\/uploads\/sites\/5\/2023\/12\/Strengths-of-CPVC-Impact-resistance6.png\" alt=\"Strengths-of-CPVC-Impact-resistance6\">\r\n\t\t\t\t<figcaption class=\"text-center\">Weight: 1kg, @0deg-C &#8211; 50% rupture height<\/figcaption>\r\n\t\t\t<\/figure>\r\n<\/div><\/div>\n<\/div>\n\n<\/div>\r\n\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<div  class=\"iframe-box\">\r\n\t<div class=\"text-center\"><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/sEpykMBX4Hs?loop=1&amp;playlist=sEpykMBX4Hs\" title=\"Impact Testing; Durastream versus competitor\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\r\n<\/div>\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n\n<div  class=\"quote-box\">\r\n\t<h3 class=\"quote-box-title\">Contact<\/h3>\r\n\t<p class=\"quote-box-text text-center\">Click here for product inquiries and sample requests.<\/p>\r\n\t<div class=\"text-center\"><a href=\"\/en\/contact\/\"><button class=\"btn btn-arrow-right hovergradient freetext size-m\"><span>Contact<\/span><\/button><\/a><\/div>\r\n<\/div>\n\n<div  class=\" spacer spacer-m\"><\/div>\r\n\n<\/div>\r\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":1207,"menu_order":26,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1212","page","type-page","status-publish","hentry"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/pages\/1212","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/comments?post=1212"}],"version-history":[{"count":36,"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/pages\/1212\/revisions"}],"predecessor-version":[{"id":3211,"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/pages\/1212\/revisions\/3211"}],"up":[{"embeddable":true,"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/pages\/1207"}],"wp:attachment":[{"href":"https:\/\/www.durastream.com\/en\/wp-json\/wp\/v2\/media?parent=1212"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}